Over 10 mio. titler Fri fragt ved køb over 499,- Hurtig levering 30 dages retur

Ultrasonic Phased Array Assessment of the Interference Fit and Leak Path of the North Anna Unit 2 Control Rod Drive Mechanism Nozzle 63 with Destructi

- Criticism of the Works of Novelists, Poets, Playwrights, Short-Story Writers, and Other Creative Writers Who Liv

Bog
  • Format
  • Bog, paperback
  • Engelsk
  • 138 sider

Normalpris

kr. 214,95

Medlemspris

kr. 194,95
  • Du sparer kr. 20,00
  • Fri fragt
Som medlem af Saxo Premium 20 timer køber du til medlemspris, får fri fragt og 20 timers streaming/md. i Saxo-appen. De første 7 dage er gratis for nye medlemmer, derefter koster det 99,-/md. og kan altid opsiges. Løbende medlemskab, der forudsætter betaling med kreditkort. Fortrydelsesret i medfør af Forbrugeraftaleloven. Mindstepris 0 kr. Læs mere

Beskrivelse

Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the effectiveness and reliability of advanced nondestructive examination (NDE) methods for the detection and characterization of flaws in nuclear power plant components. One area of concern relates to the nickel-based alloys used in primary pressure boundary components in pressurized water reactors (PWRs). Nickel-based alloys exposed to reactor coolant in PWRs may experience a form of degradation known as primary water stress corrosion cracking (PWSCC). One PWR component that has an operational history of PWSCC is the control rod drive mechanism (CRDM) nozzle. The CRDM nozzles are cylindrical penetrations in the upper reactor pressure vessel (RPV) head that allow for the insertion and removal of control rods. The penetration tube is held in place with an interference fit, and is seal-welded on the underside of the vessel head with a J-groove weld. Cracking in the nozzle or weld metal can allow borated water to leak to the top of the RPV head. Boric acid corrosion of the RPV head, as occurred at Davis Besse, is a concern, as is nozzle ejection in the presence of extensive circumferentially oriented cracking. In response to a number of observations of RPV head leakage at domestic plants, NRC regulations were modified to require PWR licensees to periodically perform a demonstrated surface or volumetric leak path assessment of all J-groove welds in the RPV head.

Læs hele beskrivelsen
Detaljer
Størrelse og vægt
  • Vægt335 g
  • Dybde0,7 cm
  • coffee cup img
    10 cm
    book img
    21,5 cm
    27,9 cm

    Anmeldelser

    Vær den første!

    Log ind for at skrive en anmeldelse.

    Findes i disse kategorier...

    Se andre, der handler om...