This report documents results from the first phase of a study co-sponsored by the
American Society of Mechanical Engineers (ASME) to assess the accuracy and precision
of manual test methods adopted by the US Environmental Protection Agency (EPA) for
determining the stack concentration of selected air pollutants. The program is entitled
Reference Method Accuracy and Precision and is referred to by the acronym ReMAP.
The Phase 1 effort addresses the precision of the selected measurement methods. The
formal Purpose Statement for the program is:
"To determine the precision of pollutant emission measurements based on
analysis of available simultaneous -- sample test data which were generated using
EPA Manual Reference Test Methods 5 and 5i (Particulate Matter), 23 (Dioxin
and Fur an), 26 (HCl), 29 (multi-metals), 101a and 101b (mercury) and 108
(arsenic) at a number of stationary air sources. "