Over 10 mio. titler Fri fragt ved køb over 499,- Hurtig levering 30 dages retur
Paperback version af Is-156 af Fema

Is-156

- Building Design for Homeland Security

Af
Bog
  • Format
  • Bog, paperback
  • Engelsk
  • 312 sider

Normalpris

kr. 329,95

Medlemspris

kr. 299,95
  • Du sparer kr. 30,00
  • Fri fragt
Som medlem af Saxo Premium 20 timer køber du til medlemspris, får fri fragt og 20 timers streaming/md. i Saxo-appen. De første 7 dage er gratis for nye medlemmer, derefter koster det 99,-/md. og kan altid opsiges. Løbende medlemskab, der forudsætter betaling med kreditkort. Fortrydelsesret i medfør af Forbrugeraftaleloven. Mindstepris 0 kr. Læs mere

Beskrivelse

Course Overview The purpose of this course is to provide guidance to the building sciences community working for public and private institutions, including Continuity of Operations (COOP) planners/managers, building officials, etc. It presents tools to help decision-makers assess the performance of their buildings against terrorist threats and to rank recommendations. It is up to the decision-makers to decide which types of threats they wish to protect against and to determine their level of risk against each threat. Those decision makers who consider their buildings to be at high risk can use this guidance as necessary Course Objectives: -Define the basic components of the assessment methodology -Define the resiliency concepts presented in the National Infrastructure Protection Plan (NIPP) -Perform an assessment for a building by identifying and prioritizing threats, consequences, and vulnerabilities, and calculating relative risk -Identify available mitigation measures applicable to the site and building envelope -Define the technology limitations and application details of mitigation measures for terrorist tactics and technological accidents -Perform an assessment for a given building by identifying vulnerabilities using the Building Vulnerability Assessment Checklist in FEMA 426 -Identify applicable mitigation measures and prioritize them based upon the final assessment risk values -Appreciate that designing a building to mitigate terrorist attacks can create conflicts with other design requirements -Understand the differences in assessing a facility for vulnerabilities to threats and how that impacts selection of that site as a COOP facility

Læs hele beskrivelsen
Detaljer
Størrelse og vægt
  • Vægt725 g
  • Dybde1,6 cm
  • coffee cup img
    10 cm
    book img
    21,5 cm
    27,9 cm

    Anmeldelser

    Vær den første!

    Log ind for at skrive en anmeldelse.