Over 10 mio. titler Fri fragt ved køb over 499,- Hurtig levering 30 dages retur

Bottomless Culvert Scour Study

- Phase II Laboratory Report

Bog
  • Format
  • Bog, paperback
  • Engelsk
  • 74 sider

Normalpris

kr. 224,95

Medlemspris

kr. 204,95
  • Du sparer kr. 20,00
  • Fri fragt
Som medlem af Saxo Premium 20 timer køber du til medlemspris, får fri fragt og 20 timers streaming/md. i Saxo-appen. De første 7 dage er gratis for nye medlemmer, derefter koster det 99,-/md. og kan altid opsiges. Løbende medlemskab, der forudsætter betaling med kreditkort. Fortrydelsesret i medfør af Forbrugeraftaleloven. Mindstepris 0 kr. Læs mere

Beskrivelse

Bottomless culverts are three-sided structures that use the natural channel for the bottom. These structures could be used to convey flows from one side of a highway to the other. As such, they are an environmentally attractive alternative to box, pipe, and pipe arch culvert designs. Bottomless culverts range in size from less than a meter (1.5 feet) to more than 10 meters (35 feet) in width. The failure of such a structure could have severe consequences similar to the failure of a bridge. On the other hand, since the cost of the foundation and scour countermeasures represents a significant portion of the cost of this type of structure, overdesign of these elements can add significantly to the cost of the project. Several dozen physical modeling configurations of bottomless culverts were tested, and the resulting scour at the entrance along the foundation and outlet was measured. Predictive equations for estimating scour depth were developed and compared to MDSHA methodology. These equations will provide guidance for the design of footing depths for bottomless culverts. The study was conducted in two phases. The first phase focused on measuring maximum scour depths at the culvert entrance and developing an analysis procedure using methods found in the literature to approximate prescour hydraulic parameters that drive the analysis. No fixed-bed experiments were conducted in the first phase to measure actual prescour hydraulic parameters. No submerged entrance experiments were conducted in the first phase. The second phase expanded the investigation to include scour measurements at the outlet, submerged entrance scour measurements, and detailed velocity and depth measurements with a prescour fixed bed at locations where maximum scour occurred. Additional tests were conducted to evaluate the use of various measures to reduce scour including wingwalls, pile dissipators, riprap, and cross vanes.

Læs hele beskrivelsen
Detaljer
Størrelse og vægt
  • Vægt195 g
  • Dybde0,3 cm
  • coffee cup img
    10 cm
    book img
    21,5 cm
    27,9 cm

    Anmeldelser

    Vær den første!

    Log ind for at skrive en anmeldelse.

    Findes i disse kategorier...

    Se andre, der handler om...